Evaluation of Thermal Radiant Environment in Livestock Building(1)
-Development of Vector Radiant Thermometer-

Shusaku KATAYAMA

Summary

    Characteristics of a Vector Radiant Thermometer (VRT meter) which is used for measuring a dirction and strength of thermal radiation is described. A theory of the VRT meter is based on hot balance at each face of a cube.
    A measurement of heat thransfer wing the VRT meter was carrid out in a wind tunnel. The convective heat transfer coefficient at ech face of the VRT meter were obtained.
    Comparison was made between value from the VRT meter, and a net radiometer and other instruments. Error of the VRT meter was within 6 percent.
    It was proved that the VRT meter can be used satisfactorily for measuring the thermal radiation environment in livestock buildings.