Summary
The number of air changes per hour (AC/h) in a typical calf hutch was measured under various conditions as a parameter of air purity. The sensible heat production from a calf was simulated by a model having a thin sheet heater on the surface of the model body. The measurement of air exchange was made using gas tracer method with carbon dioxide gas.HomePage
The following conclusions were made from this study :
1. The number of AC/h under calm conditions was more than 80.
2. Effect of roof inclines, no incline and 1/8 compared to normal incline (1/24), was not significant under calm conditions.
3. Front covers having a 50x50 cm opening and a 60x120 cm opening, Figs. 2b and 2c, decreased the number of AC/h drastically. Front quarter covers, 30x120 cm, on the bottom, top and left, Figs. 2d, 2e and 2f, had no significant effect on air exchange.
4. With a wind velocity of 1 m/s toward the front opening the number of AC/h was more than twice (182+-26.3) that under calm conditions. With the same wind velocity toward the back wall the number of AC/h was 61+-3.0.